Marklon Polyglass Polycarbonate Solid Sheet features a protective layer of high-density UV reflector, offering exceptional resistance to the damaging effects of UV light, thus minimizing long-term yellowing and hazing.
In summary, Marklon Polyglass® Polycarbonate Solid Sheet offers unparalleled UV resistance, customization options, and a comprehensive warranty, making it the ideal choice for a wide range of applications requiring durability and aesthetic appeal.





MK91 BROWN
MK92 BLUE
MK93 GREEN
MK95 CLEAR
MK98 WHITE1.0, 2.0, 3.0, 4.0, 4.5, 5.0, 6.0, 7.0, 8.0, 10.0
Up to 30500 (100′) or cut to size
1212
Item |
Test Method |
Unit |
Result |
Hardness |
ISO 868 |
Shore D |
78 |
FlexuralStrengthModulus |
ISO 178 |
MPa |
71.22,090 |
Tensile PropertiesTensile StrengthElongation at BreakTensile Modulus |
ISO 527-2 |
MPa%MPa |
65.85.72,490 |
Density |
ISO 1183-1 |
Kg / M³ |
1200 |
Water Absorption |
ISO 62 |
% |
0.08 |
Heat Deflection Temperature |
ISO 75-2 |
ºC |
135 |
Test Report |
2014PC0204 |
||
Item : Acoustics
Test Method : ISO 140-3:1995
Unit : dB
Result : 28
Test Report : 2014CB1221
Item : Atmospheric test reportTest Method : ASTM G 7-89
Type of Exposure : Direct Weathering
Duration of Exposure : Deterioration basis
No physical change such as colour change or blistering occurred after 8 years and 10 months of exposure.
Test Report : KD990041
Item :
Impact Resistance
Izod Impact (Notched)
Test Method
ASTM D 256 : 92
Pendulum : 7.5 Joule
Unit : J/m
Test Report : CB990154
Item :
Impact Resistance
Izod Impact (Notched)
Test Method
ASTM D 256
Pendulum : 2 Joule
Unit : J/m
Result : 97 ± 3
Test Report : PTS/ER13/330
Item :
Impact Resistance
Izod Impact (Notched)
Test Method :
ASTM D 256
Pendulum : 2 Joule
Unit : J/m
Result : 116 ± 7
Test Report : PTS/ER13/332



Make sure the support structure is clean and dry. Do not directly screw the sheet, only use aluminium clapping for joining. Must leave a gal of at least 5mm in between sheets for thermal expansion and contraction. A minimum slope of 5º roof pitch is recommended to allow adequate rain water run-off.



Use only new or sharp ground steel or carbide tipped drills. All holes must be drilled at least 40mm from the edge of the sheet. All holes must be at least 4mm bigger than screw for thermal expansion and contraction.

Marklon Polyglass® Polycarbonate Solid Sheet can be cold-form by : –
* a/b >= 2* Ø < 90˚* R >= 180t

Marklon Polyglass® Polycarbonate Solid Sheet’s is produced with a protective PE film on one or both sides which should be kept on until the panel is fastened. The UV protected side is to be faced towards the sun and is marked with printed film
(Marklon Polyglass®)

To install, 50mm of protective film should be peeled off from the edges of the sheet to allow clean sheet insertion into the glazing system.

The residual film should be removed immediately after the glazing is completed.
For maintenance and storage guidelines

Sheets should be kept indoor, protected from sunlight and rain fall by an appropriate opaque waterproof roof cover.

Use only neutral detergent or mild soap for cleaning. Wash by using soft cloth op sponge. Rinse off with lukewarm water (below 60˚C)
Use only neutral silicone for polycarbonate.

Use circular saw blade for cutting Marklon Polyglass® Polycarbonate Solid

Please feel free to contact our customer service chat during working hours.
Working hours: 8.30 am – 5.00 pm
Saturday – Thursday, excluding public holiday & Friday
Whatsapp us now for more information:
At Kee Maju Jaya Trading Sdn Bhd, we are more than just a building materials supplier—we are your trusted partner in building stronger, more resilient communities.